THE DETERMINATION OF THE EQUIVALENT CURRENT LOAD WHILE TESTING THE TRACTION MOTORS ON THE HEAT WITHOUT VENTILATION

L. V. Dubynets, D. V. Ustymenko, P. O. Loza

Abstract


The theoretical determination procedure of an equivalent loading current in tests of traction electric motors on heating without ventilation is offered. The results of calculation of an equivalent current for traction engine ED-118A are presented, as well as the method accuracy is experimentally confirmed.


Keywords


ventilation; equivalent current; test; load; motor; heating

GOST Style Citations


1. Правила ремонту електричних машин тепловозів ЦТ 0064 [Текст]. – 2003. – 122 с.

2. Правила ремонту електричних машин електровозів ЦТ 0063 [Текст]. – 2003. – 286 с.

3. Находкин, М. Д. Электрические машины постоянного тока [Текст] / М. Д. Находкин. – М.: Энергия, 1960.

4. Курбасов, А. С. Проектирование тяговых электродвигателей [Текст] / А. С. Курбасов. – М.: Транспорт, 1987. – 536 с.