IMPROVING THE EFFICIENCY OF THE PROTECTION CIRCUIT OF THE TRACTION MOTORS FROM EXTERNAL AND INTERNAL SHORT CIRCUITS DURING REGENERATIVE BRAKING ON ELECTRIC LOCOMOTIVES DE1

M. H. Visyn, B. T. Vlasenko, O. I. Kyiko, O. O. Yehorov

Abstract


The article deals with the analysis of the work of Traction Motor Protecting System on electric locomotives DE1, which protects the motors from inner and outer short circuits in the mode of recuperative breaking. The calculations have revealed that the system in question, installed by the producer, does not meet the requirements of protecting the motors from short circuits in the recuperative mode. For extra protection of the motors from outer, and especially – from inner short circuits, the authors suggest complementing the system by quick-acting contactors from the «earth» side, with automatic forced demagnetization of traction motor excitation windings, operating in generator mode, with the recuperative current during the protection activation.


Keywords


Traction Motor Protecting System; electric locomotives DE1; in generator mode

GOST Style Citations


1. Мацне В. Д. Исследование электрооборудования электроподвижного состава постоянного тока / В. Д. Мацнев, А. С. Курбасов, Б. С. Сухоруких, Ю. И. Чуверин // Труды ВНИИЖТ. – М.: Транспорт, 1959. – С. 21.

2. Захарченко Д. Д. Подвижной состав электрических железных дорог. Тяговые машины и трансформаторы / Д. Д. Захарченко, Н. А. Ротанов, Е. В. Горчаков, П. Н. Шляхто. – М.: Транспорт, 1968. – С. 104–108.

3. Рунов Ю. А. Исследование электромагнитных переходных процессов в тяговых двигателях электроподвижного состава // Труды ЦНИИ МПС «ВНИИЖТ». – М.: Транспорт, 1974. – Вып. 516. – С. 78–92.





Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.

 

ISSN 2307–3489 (Print)